麦田学社 下载中心 EN 13381-2-2014 对结构部件耐火性作用的检测方法.第2部分_垂直保护膜.pdf

版块导航

热门下载

麦田学社 © my678.cn

EN 13381-2-2014 对结构部件耐火性作用的检测方法.第2部分_垂直保护膜.pdf

 

EN 13381-2-2014 对结构部件耐火性作用的检测方法.第2部分:垂直保护膜:
标准号:EN 13381-2-2014
实施状态:现行
中文名称:对结构部件耐火性作用的检测方法.第2部分:垂直保护膜
英文名称:Test methods for determining the contribution to the fire resistance of structural members - Part 2: Vertical protective membranes
发布日期:2014-09
代替标准:ENV 13381-2-2002;FprEN 13381-2-2014
采用标准:DIN EN 13381-2-2014,IDT;BS EN 13381-2-2014,IDT;NF P92-140-2-2014,IDT;SN EN 13381-2-2014,IDT;OENORM EN 13381-2-2014,IDTN-EN 13381-2-2014,IDTN-EN 13381-2-2016,IDT;SS-EN 13381-2-2014,IDT;UNE-EN 13381-2-2016,IDT;TS EN 13381-2-2016,IDT;DS/EN 13381-2-2015,IDT;UNI EN 13381-2:2014-2014,IDT;STN EN 13381-2-2015,IDT;CSN EN 13381-2-2014,IDT;DS/EN 13381-2-2015,IDT;NEN-EN 13381-2:2014 en-2014,IDT;SFS-EN 13381-2:en-2014,IDT
标准简介:This European Standard specifies a test method for determining the ability of a vertical protective membrane, when used as a fire resistant barrier, to contribute to the fire resistance (loadbearing capacity R) of loadbearing vertical structural building members fabricated from steel, concrete, steel/concrete composites or timber. The method described is applicable to any type of vertical protective membrane, which can be associated with a separate bracing membrane. The vertical protective membrane can be either separated from or attached to the structural building member and is self-supporting. This test method is applicable to vertical protective membranes where there is a gap and a cavity between the vertical protective membrane and the structural building member, otherwise alternative test methods prEN 13381-3, EN 13381-4, EN 13381-6 or prEN 13381-7 should be used as appropriate. This test method and assessment is not applicable to the following: a) all situations where the cavity is to be used as a service or ventilation shaft; b) all situations where the vertical protective membrane acts as a bracing membrane. This European Standard contains the fire test which specifies the tests which shall be carried out whereby the vertical protective membrane together with the structural member to be protected is exposed to the specified fire. The fire exposure, to the standard temperature/time curve given in EN 1363-1, is applied to the side which would be exposed in practice. The test method makes provision, through specified optional additional procedures, for the collection of data which can be used as direct input to the calculation of fire resistance according to the processes given in EN 1992-1-2, EN 1993-1-2, EN 1994-1-2 and EN 1995-1-2. This European Standard also contains the assessment which provides information relative to the analysis of the test data and gives guidance for the interpretation of the results of the fire test, in terms of loadbearing capacity c
文件格式:PDF
文件大小:1.16MB
文件页数:40
(以上信息更新时间为:2019-11-28)



文档语言及版本参照下方封面截图:
EN 13381-2-2014 对结构部件耐火性作用的检测方法.第2部分:垂直保护膜
点击下方链接查看更多内容。