标准号:CEN/TS 16637-1-2014
实施状态:现行
中文名称:建筑产品.危险物质排放的评估.第1部分:浸出试验和附加试验步骤的试验指南
英文名称:Construction products - Assessment of release of dangerous substances - Part 1: Guidance for the determination of leaching tests and additional testing steps
发布日期:2014-08
代替标准:FprCEN/TS 16637-1-2013
采用标准:DIN CEN/TS 16637-1-2014,IDT

D CEN/TS 16637-1-2014,IDT;SNR CEN/TS 16637-1-2014,IDT;ONR CEN/TS 16637-1-2014,IDT;SIS-CEN/TS 16637-1-2015,IDT;TSE CEN/TS 16637-1-2015,IDT;DS/CEN/TS 16637-1-2014,IDT;CEN/TS 16637-1:en-2014,IDT;UNI CEN/TS 16637-1:2014-2014,IDT;STN P CEN/TS 16637-1-2014,IDT;CSN P CEN/TS 16637-1-2015,IDT;DS/CEN/TS 16637-1-2014,IDT;NPR-CEN/TS 16637-1:2014 en-2014,IDT
标准简介:This Technical Specification allows the identification of the appropriate leaching test method for the determination of the release of Regulated Dangerous Substances from construction products into soil, surface water and groundwater. This document provides a stepwise procedure for the determination of appropriate release tests, including: a) guidance for the identification of construction products potentially emitting Regulated Dangerous Substances; b) determination of the test method based on general product properties; c) choice of the test method using specific product properties. Furthermore, this Technical Specification gives general guidance for CEN Technical Product Committees on basic aspects (sampling, sample preparation and storage, eluate treatment, analysis of eluates and documentation) to be specified in the relevant product standards. Metallic products, coatings on metallic products and organic coatings for metals are not considered in the determination scheme of this Technical Specification since the test method in CEN/TS 16637-2 (tank test) is not appropriate for the testing of these construction products due to a different release mechanism (solubility control). NOTE Metallic products are excluded from the scope of CEN/TS 16637-2 because the principles of that test (diffusion) are not obeyed by these products. Metallic products have shown pH dependent solubility control, which means that metals released from the oxidation layer on the metal until the maximum possible solubility level at the prevailing pH conditions in the surrounding water is reached (more water in contact with the same metal surface means more metals released and more time does not lead to more release due to solubility control). Maximum level of release can often be reached in minutes to hours. More generally, it can be stated that expression of results for metallic surfaces in mg/(m2-s) is always "conditional", i.e. dependent on the local conditions at which the measurements wer
文件格式:PDF
文件大小:1.44MB
文件页数:52
(以上信息更新时间为:2019-11-28)
文档语言及版本参照下方封面截图:

点击下方链接查看更多内容。