麦田学社 下载中心 标准分享 国际标准 IEC 60730-2-5-2000 家用和类似用途的电气自动控制器 第2-5部分_燃烧器电气自动控制系统的特殊要求.pdf

IEC 60730-2-5-2000 家用和类似用途的电气自动控制器 第2-5部分_燃烧器电气自动控制系统的特殊要求.pdf

 

IEC 60730-2-5-2000 家用和类似用途的电气自动控制器 第2-5部分:燃烧器电气自动控制系统的特殊要求:
标准号:IEC 60730-2-5-2000
实施状态:作废
中文名称:家用和类似用途的电气自动控制器 第2-5部分:燃烧器电气自动控制系统的特殊要求
英文名称:Automatic electrical controls for household and similar use - Part 2-5: Particular requirements for automatic electrical burner control systems
发布日期:2000-04
被替代标准:IEC 60730-2-5-2013
代替标准:IEC 72/430/FDIS-1999;IEC 60730-2-5-1993;IEC 60730-2-5 AMD 1-1996;IEC 60730-2-5 AMD 2-1997
采用标准:DIN EN 60730-2-5-2003,MOD;DIN EN 60730-2-5-2005,MOD;ANSI/UL 372-2007,MOD;BS EN 60730-2-5+A2-2002,MOD;GB 14536.6-2008,IDT;EN 60730-2-5-2002,MOD;prEN 60730-2-5-2001,MOD;NF C47-735-2002,MOD;JIS C 9730-2-5-2004,MOD;JIS C 9730-2-5-2010,MOD;OEVE/OENORM EN 60730-2-5-2003,MOD;OEVE/OENORM EN 60730-2-5+A1+A11-2005,MODN-EN 60730-2-5-2006,MOD;UNE-EN 60730-2-5-2004,MOD
起草单位:IEC/TC 72
标准简介:This clause of part 1 is applicable except as follows:
1  Replacement:
This part of IEC 60730 applies to automatic electrical burner control systems for the automatic control of burners for oil, gas, coal or other combustibles for household and similar use including heating, air conditioning and similar use.
This part 2-5 is applicable to a complete burner control system and to a separate programming. unit. This part 2-5 is also applicable to a separate electronic high-voltage ignition source and to a separate flame detector.
Separate ignition devices (electrodes, pilot burners, etc.) are not covered by this part 2-5 unless they are submitted as part of a burner control system.
Requirements for separate ignition transformers are contained in IEC 60989.
Throughout this part 2-5, where it can be used unambiguously, the word "system" means "burner control system" and "systems" means "burner control systems".
Systems utilizing thermoelectric flame supervision are not covered by this part 2-5.
1.1  This part 2-5 applies to the inherent safety, to the manufacturer's declared operating values, operating times and operating sequences where such are associated with burner safety and to the testing of automatic electrical burner control systems used in, on, or in association with, burners.
Requirements for specific operating values, operating times and operating sequences are given in the standards for ' appliances and equipment.
Systems for equipment not intended for normal household use, but which nevertheless may be used by the public, such as equipment intended to be used by laymen in shops, in light industry and on farms, are within the scope of this part 2-5.
This part 2-5 applies to systems using NTC or PTC thermistors, additional requirements for which are contained in annex J.
This part 2-5 does not apply to systems designed exclusively for industrial applications.
1.2  This part 2-5 applies to manual controls when such are electrically and/or mechanically integral with automatic controls.
Requirements for manual switches not forming part of an automatic control are contained in IEC 61058-1. Throughout this part 2-5, the word "equipment" means "appliance and equipment".
2  Replacement:
This part 2-5 applies to systems with a rated voltage not exceeding 660 V and with a rated current not exceeding 63 A.
3  Replacement:
This part 2-5 does not take into account the response value of an automatic action of a control, if such a response value is dependent upon the method of mounting the control in the equipment. Where a response value is of significant purpose for the protection of the user, or surroundings, the value defined in the appropriate household equipment standard or as determined by the manufacturer applies.
This part 2-5 includes systems responsive to flame properties.
4  Replacement:
This part 2-5 applies also to systems incorporating electronic devices, requirements for which are contained in annex H.
5  Normative references:
This clause of part 1 is applicable except as follows:
Addition:
IEC 60068-2-6:1995, Environmental testing - Part 2: Tests - Test Fc: Vibration (sinusoidal)
IEC 60384-16:1982, Fixed capacitors for use in electronic equipment - Part 16: Sectional specification: Fixed metallized polypropylene film dielectric d.c. capacitors
IEC 60989:1991, Separating transformers, autotransformers, variable transformers and reactors
文件格式:PDF
文件大小:10.56MB
文件页数:104
(以上信息更新时间为:2019-11-25)



文档语言及版本参照下方封面截图:
IEC 60730-2-5-2000 家用和类似用途的电气自动控制器 第2-5部分:燃烧器电气自动控制系统的特殊要求
点击下方链接查看更多内容。