ISO/ASTM 51939-2005 血液辐照剂量测定的实施规程

[复制链接]
查看6383 | 回复5 | 2018-5-16 01:52 | 显示全部楼层 |阅读模式
标准号:ISO/ASTM 51939-2005
实施状态:作废
中文名称:血液辐照剂量测定的实施规程
英文名称:Practice for blood irradiation dosimetry
发布日期:2005-05
被替代标准:ISO/ASTM 51939-2013
代替标准:ISO/ASTM 51939-2002;ISO/ASTM DIS 51939-2004
采用标准:ASTM/ISO 51939-2005,IDT
起草单位:ISO/TC 85
标准简介:1   This practice outlines irradiator installation qualifica-tion, operational qualification, performance qualification, and routine product processing dosimetric procedures to be fol-lowed in the irradiation of blood and blood components by the blood-banking community. If followed, these procedures will help to ensure that the products processed with ionizing radiation from gamma, X-rays (bremsstrahlung), or electron sources receive absorbed doses within a predetermined range.
2  This practice covers dosimetry for the irradiation of blood for these types of irradiators: self-contained irradiators (free-standing irradiators) utilizing <up137>Cs, <up60>Co or X-rays (bremsstrahlung), teletherapy units, and electron accelerators. The absorbed dose range for blood irradiation is typically 15 Gy to 50 Gy. In some jurisdictions, the absorbed dose range for blood irradiation is 25 Gy to 50 Gy.
3  The energy range is typically from approximately 40 keV to 5 MeV for photons, and up to 10 MeV for electrons.
4  This practice also covers the use of radiation-sensitive indicators for the visual and qualitative indication that the product has been irradiated.
5  This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appro-priate safety and health practices and to determine the applicability or regulatory limitations prior to use.
文件格式:PDF
文件大小:267.39KB
文件页数:18
(以上信息更新时间为:2019-11-22)