[欧洲标准] CEN/TS 16115-1-2011 环境空气质量的测量.第1部分:确定模具使用滤波器采样系统和文化分析

[复制链接]
查看1698 | 回复4 | 2011-4-3 20:18 | 显示全部楼层 |阅读模式
标准号:CEN/TS 16115-1-2011
实施状态:现行
中文名称:环境空气质量的测量.第1部分:确定模具使用滤波器采样系统和文化分析
英文名称:Ambient air quality - Measurement of bioaerosols - Part 1: Determination of moulds using filter sampling systems and culture-based analyses
发布日期:2011-04-01
代替标准:FprCEN/TS 16115-2010
采用标准:DIN CEN/TS 16115-1-2011,IDT;BS DD CEN/TS 16115-1-2011,IDT;XP X43-047-1-2011,IDT;ONR CEN/TS 16115-1-2011,IDT;SIS-CEN/TS 16115-1-2011,IDT;UNE-CEN/TS 16115-1-2013,IDT;CEN/TS 16115-1:en-2011,IDT;UNI CEN/TS 16115-1:2011-2011,IDT;STN P CEN/TS 16115-1-2011,IDT;CSN P CEN/TS 16115-1-2011,IDT;DS/CEN/TS 16115-1-2011,IDT;NPR-CEN/TS 16115-1:2011 en-2011,IDT
标准简介:This Technical Specification describes the measurement of moulds in ambient air in order to identify, quantify and characterize bioaerosol pollution in ambient air resulting from emissions from different sources. The method described specifies the sampling of moulds as part of the suspended particulate matter (SPM, here particles with aerodynamic diameter up to ca. 30 μm) using a filter sampling system with gelatine/poly-carbonate filter combination followed by the culture-based analyses on DG18 agar. The sampling duration can be varied between 10 min to 24 h. The health effect of bioaerosols is not limited to any particle fraction, therefore,This document describes the sampling of moulds as part of the suspended particulate matter as a convention method. NOTE The sampling method described inThis document in principle is likely to be appropriate for the sampling of actinomycetes and other spore-forming bacteria (resistant to desiccation). For these species a special analytical procedure using different culture media should be applied, butThis is not within the scope of this document. The standard method set out inThis Technical Specification is accepted by convention as reference method. The measured quantity, here the number of colony forming units per cubic meter (CFU/m3), is determined by the inlet design of the sampling head, the associated operational parameters and the analytical procedure. Standardized methods for sampling, detection and enumeration of moulds including standards for sampling strategies are important for comparative assessment of moulds in ambient air. Before doing any measurements a plan for the measurement strategy is necessary (see CEN/TS 16115-2). WARNING-The use of this Technical Specification may involve hazardous materials, operations and equipment.This Technical Specification does not purport to address all the safety problems associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.
文件格式:PDF
文件大小:992.78KB
文件页数:50
(以上信息更新时间为:2019-11-28)

CEN_TS 16115-1-2011 环境空气质量的测量.第1部分_确定模具使用滤波器采样系统和文化分析.pdf (992.78 KB)

使用道具 举报