[欧洲标准] EN 1948-1-2006 固定源排放限值.PCDDs/PCDFs和类二氧芑PCBs的质量浓度的测定.第1部分:PCDDs/PCDFs的抽样

[复制链接]
查看9218 | 回复0 | 2010-4-20 19:58 | 显示全部楼层 |阅读模式
标准号:EN 1948-1-2006
中文名称:固定源排放限值.PCDDs/PCDFs和类二氧芑PCBs的质量浓度的测定.第1部分:PCDDs/PCDFs的抽样
英文名称:Stationary source emissions - Determination of the mass concentration of PCDDs/PCDFs and dioxin-like PCBs - Part 1: Sampling of PCDDs/PCDFs
发布日期:2006-03-01
代替标准:EN 1948-1-1996
采用标准:DIN EN 1948-1-2006,IDT;BS EN 1948-1-2006,IDT;NF X43-324-1-2006,IDT;SN EN 1948-1-2006,IDT;OENORM EN 1948-1-2006,IDT;PN-EN 1948-1-2006,IDT;SS-EN 1948-1-2006,IDT;UNE-EN 1948-1-2007,IDT;UNI EN 1948-1:2006-2006,IDT;STN EN 1948-1-2006,IDT;CSN EN 1948-1-2006,IDT;DS/EN 1948-1-2006,IDT;NEN-EN 1948-1:2006 en-2006,IDT;SFS-EN 1948-1:en-2006,IDT
标准简介:This European Standard has been developed to measure PCDD/PCDF concentrations at about
0,1 ng I-TEQ/m3 in stationary source emissions.
This European Standard specifies both method validation and a framework of quality control requirements
which shall be fulfilled by any PCDD/PCDF sampling.
The user has the possibility to choose between three different methods:
⎯ "filter/condenser method"
⎯ "dilution method"
⎯ "cooled probe method"
Each sampling method is illustrated by some sampling systems described in detail in Annex B as examples of
proven procedures.
During comparison measurements of the three sampling methods on municipal waste incinerators at the level
of about 0,1 ng I-TEQ/m3 these methods have been deemed comparable within the expected range of
uncertainty. Validation trials were performed on the flue gas of municipal waste incinerators at the level of
about 0,1 ng I-TEQ/m3 and a dust loading of from 1 mg/m3 to 15 mg/m3. Although this European Standard is
primarily developed and validated for gaseous streams emitted by waste incinerators, the practical experience
shows that it can be applied for wide concentration ranges and various emission sources.
The procedure described in the three parts of EN 1948 specifies requirements which shall be met in order to
measure the 17 congeners necessary to calculate the total I-TEQ (see Table A.1).
Besides the determination of PCDDs/PCDFs the described measurement methods are suitable for
determination of other low-volatile substances, e.g. of dioxin-like PCBs (details for sampling and analyses see
CEN/TS 1948-4), although no validated performance characteristics are available yet.
文件格式:PDF
文件大小:1008.01KB
文件页数:68


标准全文下载:
EN 1948-1-2006 固定源排放限值.PCDDs_PCDFs和类二氧芑PCBs的质量浓度的测定.第1部分_PCDDs_PCDFs的抽样.pdf (1008.01 KB)

使用道具 举报