标准号:ISO/ASTM 52116-2002
实施状态:作废
中文名称:自带的干式存储γ射线辐照器的剂量测定实施规范
英文名称:Practice for dosimetry for a self-contained dry-storage gamma-ray irradiator
发布日期:2002-12
被替代标准:ISO/ASTM 52116-2013
代替标准:ISO/ASTM DIS 52116-2002
起草单位:ISO/TC 85
标准简介:1 This practice outlines dosimetric procedures to be fol-lowed with self-contained dry-storage gamma-ray irradiators. If followed, these procedures will help to ensure that calibra-tion and testing will be carried out with acceptable precision and accuracy and that the samples processed with ionizing radiation from gamma rays in a self-contained dry-storage irradiator receive absorbed doses within a predetermined range.
2 This practice covers dosimetry in the use of dry-storage gamma-ray irradiators, namely self-contained dry-storage <up137>Cs or <up60>Co irradiators (shielded freestanding irra-diators). It does not cover underwater pool sources, panoramic gamma-ray sources such as those raised mechanically or pneumatically to irradiate isotropically into a room or through a collimator, nor does it cover self-contained bremsstrahlung x-ray units.
3 The absorbed dose range for the use of the dry-storage self-contained gamma-ray irradiators covered by this practice is typically 1 to 10<up5> Gy, depending on the application. The absorbed-dose rate range typically is from 10<up-2> to 10<up3> Gy/min.
4 This practice describes general procedures applicable to all self-contained dry-storage gamma-ray irradiators. For pro-cedures specific to dosimetry in blood irradiation, see ISO/ ASTM Practice 51939. For procedures specific to dosimetry in radiation research on food and agricultural products, see ISO/ASTM Practice 51900. For procedures specific to radia-tion hardness testing, see ASTM Practice E 1249. For proce-dures specific to the dosimetry in the irradiation of insects for sterile release programs, see ISO/ASTM Guide 51940. In those cases covered by ISO/ASTM Practices 51939, 51900, 51940, or ASTM E 1249, those standards take precedence. In addition, this practice does not cover absorbed-dose rate calibrations of radiation protection instrumentation.
5 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.
文件格式:PDF
文件大小:388.53KB
文件页数:18
(以上信息更新时间为:2019-11-23)
ISO_ASTM 52116-2002 自带的干式存储γ射线辐照器的剂量测定实施规范.pdf
(388.53 KB)
|
|